الوصف
- 304 stainless steel chamber , which is widely used in food industry,medical ,considered to be stabe and durable,safety and reliable. Length-37.5 inch, diameter-2.5 inch, inlet/outlet 3/4”, no requirement of the water flow direction.
- Our high quality quartz sleeve not only provide an interspace for the 40W UV lamp, but also ensure high transmittance (90%) for the UV light. the quartz sleeve are proved to be reliable in different temperature, pressure, pH. And the only materials that will contact with your water.
- Our 40W UV water sterilizer provide enough UV light to destory the DHA of the microbe and bacteria. ensure a 99.99% reducing of bacteria and microbe in the water. The corresponding UV exposure is 30 mJ/cm2. A slower flow rate, a higher wattage device or two sterilizer might be effective to handle a strong bacteria and microbe problem.
- Intelliegnet electronic ballast support our UV Sterilzer , powered the UV lamp , work as a controller in the system with 3.6ft(110cm) power cord and lamp cord. Green light on 'work' means the system work well, Red light blinks on 'fault' , and the controller beeps when they system is failed.
- Easy installation and maintenance. No need for chemical supplement, the equipment is intended to be installed in the pipe system permanently. the lamp needs to be replaced annually and the quartz sleeve should be cleaned every 6-12 months, replace every 2 years.
- ›See more product details
NOTICE:Pre-treatment:Water quality is extremely important for the optimum performance of your UV system. The following levels are recommended :Iron < 0.3 ppm (0.3 mg/L)Hardness< 7 gpg (120 mg/L)Turbidity < 1 NTUManganese < 0.05 ppm (0.05 mg/L)Tannins < 0.1 ppm (0.1 mg/L)UV Transmittance> 75%Hot Water WarningThe water in the chamber of this equipment can be very hot (Approx 140F) during an extended 4 hours of no water flowing. It's recommended to open the faucet until the hot water has been purged from the chamber. Keep human body away from the faucet during this time. Or install a 5 gallons water tank after the UV unit to reduce the temporary hot water.MaintenanceUV lamp: Replace the UV lamp annually (or biennially if seasonal home use) to ensure maximum disinfection.Quartz Sleeve: Clean the quartz sleeve every 6-12 months, replace every 24 months. The coating on the quartz sleeve will slowly form due to the minerals in the water. This coating must be removed because it reduces the amount of UV light reaching the water, thereby reducing disinfection performance. If the sleeve can not be cleaned, it must be replaced.