🔧 Power Up Your Projects with Precision!
The OONODPST 1NO 1NC 8Amp Power Relay Module is a versatile and compact solution for controlling electrical devices with both AC and DC 12V signals. Featuring a robust 8A rating and dual functionality, this relay module is designed for easy installation and real-time monitoring, making it an essential tool for any professional looking to enhance their projects.
G**L
Perfect product to de-power a pulse output from a flow meter to sampler
I ran into the issue where I had to flow-pace a sampler via a flow meter's pulse output. The flow meter had a powered pulse output, and the sampler had a powered pulse input. The two loop powers negated each other, so I had to find a module to de-power the pulse loop, and still provide a dry normally-open contact. This product worked perfectly for very a very reasonable price. This will work for samplers, wireless telemetry systems, SCADA, and anything else needing a dry contact closure. Only the powered loop pulse output is needed. I did not need any additional DC power to power this module. Go With The Flow!
C**Z
Great little switch for the money
This is a great little device for the price. It performs as advertised. I have several of them operating in various modes. both Normally open and normally closed. I have not had any issues with them.
J**R
Great for installing a thermostat to a boiler radiant floor heat system with no "C" wire.
The relay module is much smaller than I expected which is a good thing. The small size made it easy to mount inside the boiler control box. I only had three wires from the boiler control to the heat only thermostat. The battery powered thermostat only required two wires. I was able to use the OONO relay module to convert the unused third wire to a “C” wire by connecting a 24VAC transformer to power the thermostat. In that configuration, I was then able to replace the thermostat with a Honeywell Home RTH9585WF1004 Wi-Fi Smart Color Thermostat. I wired the OONO relay module as follows: 24VAC Transformer output red wire to thermostat R port; 24VAC Transformer output black wire to OONO input green wire and to thermostat C port; OONO input blue wire to thermostat W port; OONO SW1 (normally open) C1 red wire to boiler control S1 port; OONO SW1 No1 black wire to boiler control S2 port. The OONO SW2 (normally closed) wires are unused in this configuration. It works perfectly, no issues.
H**D
Works ok
I have this installed with a very light load. So far so good but I’m still feeling it’s going to fail when I need it the most.
H**V
Great Relay
Upgraded my cart to lithium battery and had to rework the charging port to 120v. The original port had a charging interlock switch safety system that prevents the cart from moving when the cord is plugged in and charging. Since that system used the 48v coming in from the charger to send power to the interlock switch, I had to use the 120v power going to the charger in the cart to do the same thing. The easiest option was to tap into the 120v inside the charger which I ran to the relay. The red wire on the NC end goes to the 48v lithium battery and the black wire runs to the charging interlock switch. When the cart isn't plugged in, that switch is closed passing 48v to the interlock switch. When it's plugged in, the relay trips and power is cut to the switch and the cart won't run. I'll probably wire up the unused normally open circuit to some LED lights to show it's charging when plugged in. So you could get two uses out of this relay.
D**.
I use the opposing relay function
Replaced my home’s chlorine pump that runs when my well pump runs. New pump needed to stay powered all of the time. I used the chlorine pump’s remote stop function along with the dry contact on this module to stop the chlorine pump when the well pump stopped. Works like a charm.
J**.
0/2 Working Units
Have a simple 24VAC fan wire that I wanted to splice this relay into, using the Normally Closed side, that would trigger on my ERV fan when the main unit fan turns on. Ordered 1 and found the LED worked, but NC/NO side did not change with current change/LED being on/off. Figured it was a fluke, sent for a replacement, same issue with #2. Will be looking elsewhere
S**O
Awesome relay
These solid state relays are awesome. They are easy to wire and give you access to both the normally open and closed connections very easily even if you only need open or closed they give you an extra point of connection if you'll ever need it.
ترست بايلوت
منذ أسبوع
منذ 3 أيام